Beam Expander
X500III Pro includes one 1.6X beam expander for uniformity of line width that presents outstanding quality and reliability.
X500III Pro | |||||
---|---|---|---|---|---|
Laser Source | 100W | 130W | 150W | ||
Sealed CO2 Laser | |||||
Laser Cooling | Water Cooled | ||||
Working Area | w/o Honeycomb Table | 51 x 36 in. (1300 x 916 mm) | |||
with Honeycomb Table | 50.3 x 35.2 in. (1280 x 896 mm) | ||||
Max. Part Size (L x W x H) | w/o Cutting Table | 52.9 x 36.0 x 2.1 in. (1346 x 916 x 55 mm) | |||
Doors Open | 52.9 x ∞ x 1.1 in. (1346 x ∞ x 30 mm) | ||||
with Honeycomb Cutting Table | 48.8 x 32.2 x 1.1 in. (1240 x 818 x 30 mm) | ||||
with Grid Cutting Table | 52.1 x 35 x 1.1 in. (1325 x 889 x 30 mm) | ||||
Dimensions | 74.8 x 55.1 x 47.2 in. (1900 x 1400 x 1200 mm) | ||||
Driving Motor | Closed-loop DC servo control | ||||
Maximum Motor Speed | 40 IPS | ||||
Speed Control | Adjustable from 0.1~100% (Up to 16 color-linked speed settings per job) | ||||
Power Control | Adjustable from 0~100% (Up to 16 color-linked power settings per job) | ||||
Engraving Capability | 256-level gray scale image processing capability | ||||
Distance Accuracy | 0.254 mm or 0.1% of move, whichever is greater | ||||
Z-Axis Movement | Manual | ||||
Resolution (DPI) | Available 125, 250, 300, 500, 600, 1000 | ||||
Interface | 10 Base-T Ethernet USB Type-A 2.0 – For USB storage (Max. 32GB capacity, FAT file system) USB Type-B 2.0 – For connecting with the computer | ||||
Focus Lens | Standard 2",Optional 3" | Standard 3",Optional 2" | |||
Display Panel | 4-line LCD panel showing current file name, total working time, laser power, engraving speed, file(s) loaded into memory buffer, setup and diagnostic menus. | ||||
Safety | Class I Laser Product Compliant with EN60825 Class II Laser Product Compliant with CDRH 2006/42/EC Machinery Directive Compliance Class 4 Laser Product Compliant with CDRH with the optional pass-through door module | ||||
Cutting Table | Knife-shaped cutting bars with down vacuum and scrap collecting funnel | ||||
Facility Requirements | |||||
Operation Voltage | 200-240VAC, 50/60Hz auto switching, Max.10A | ||||
Fume Extraction System | External exhaust system with minimum flow rate 2160m3/h (CFM 1273 ft3/h) is required,2.5kPA negative pressure (Pure-Air PA-2400FS @ 8" exhaust port) | ||||